REVERSE FLAME STEEL BOILER
PIROSOLID
18 – 25 – 40 kW

PIROSOLID 18
18 kW
REVERSE FLAME STEEL BOILER.
ANALOGUE CONTROL.
BOILER SUPPLIED WITHOUT HOPPER.
FOR SOLID FUELS (FIREWOOD) WITH REVERSE FLAME OR GASIFICATION BY PYROLYTIC COMBUSTION.
THE REGULATION ACTS ON THE FUME EXTRACTOR, ACHIEVING EFFICIENCIES OF 90%.
PIROSOLID 25
25 kW
REVERSE FLAME STEEL BOILER.
ANALOGUE CONTROL.
BOILER SUPPLIED WITHOUT HOPPER.
FOR SOLID FUELS (FIREWOOD) WITH REVERSE FLAME OR GASIFICATION BY PYROLYTIC COMBUSTION.
THE REGULATION ACTS ON THE FUME EXTRACTOR, ACHIEVING EFFICIENCIES OF 90%.
PIROOLID 40
40 kW
REVERSE FLAME STEEL BOILER.
ANALOGUE CONTROL.
BOILER SUPPLIED WITHOUT HOPPER.
FOR SOLID FUELS (FIREWOOD) WITH REVERSE FLAME OR GASIFICATION BY PYROLYTIC COMBUSTION.
THE REGULATION ACTS ON THE FUME EXTRACTOR, ACHIEVING EFFICIENCIES OF 90%.
INSTALLATION CONDITIONS
1. Maximum firewood humidity of 20%.
2. Anti-condensation valve to keep the body at a minimum of 72ºC.
3. Proper size chimney to achieve the adequate depression, which cannot exceed 0.5 m horizontally.
– Mandatory chimney draft for Pirosolid 18-25-40: 23 Pa.
4. Boiler loaded according to demand.
5. Operation via buffer tank.
– For Pirosolid 18 : Minimum 500 L. Recommended 900 L. – For Pirosolid 25: Minimum 750 L. Recommended 1250 L.
– For Pirosolid 40: Minimum 1000 L. Recommended: 2000 L.

Válvula anticondensación.
MANDATORY INSTALLATION
Buffer tank
INERPLUS

RECOMMENDED INSTALLATION
Draft stabiliser

To extend the useful life of the boiler and for fuel savings, maintenance and greater convenience.